Resources · Research Data

Structural model database — downloads

All 34 OpenSees RC SMF models: 30 in the primary ASCE 7-02 design set plus 4 comparative ASCE 7-05 designs.

Two-dimensional three-bay frame models · 1–20 stories

The models below are two-dimensional three-bay RC special moment frame models. Full design documentation is in the summary tables PDF. Every model requires the template files and setup covered on the Structural Model Database page.

Primary design set — ASCE 7-02

Stories Frame type Design variant Model ID Download
1-story Space Frame Baseline design 2061 Zip file
1-story Space Frame Pinned base 2062 Zip file
1-story Space Frame Fixed base 2063 Zip file
1-story Perimeter Frame Baseline design 2069 Zip file
2-story Space Frame Baseline design 1001 Zip file
2-story Space Frame Pinned base 1001a Zip file
2-story Space Frame Fixed base 1002 Zip file
2-story Perimeter Frame Baseline design 2064 Zip file
4-story Perimeter Frame Baseline design 1003 Zip file
4-story Perimeter Frame Uniform elements 1004 Zip file
4-story Space Frame Baseline design 1008 Zip file
4-story Perimeter Frame 30’ bays 1009 Zip file
4-story Space Frame 30’ bays 1010 Zip file
8-story Perimeter Frame Baseline design 1011 Zip file
8-story Space Frame Baseline design 1012 Zip file
8-story Space Frame Uniform elements 1022 Zip file
8-story Space Frame Weak story design #1 2065 Zip file
8-story Space Frame Weak story design #2 2066 Zip file
8-story Space Frame Weak story design #3 1023 Zip file
8-story Space Frame Weak story design #4 1024 Zip file
12-story Perimeter Frame Baseline design 1013 Zip file
12-story Space Frame Baseline design 1014 Zip file
12-story Space Frame Uniform elements 1015 Zip file
12-story Space Frame Weak story design #1 2067 Zip file
12-story Space Frame Weak story design #2 2068 Zip file
12-story Space Frame Weak story design #3 1017 Zip file
12-story Space Frame Weak story design #4 1018 Zip file
12-story Space Frame 30’ bays 1019 Zip file
20-story Perimeter Frame Baseline design 1020 Zip file
20-story Space Frame Baseline design 1021 Zip file

Comparative design set — original ASCE 7-05 (before Supplement #2)

Due to the removal of the minimum base shear requirement, these buildings have substantially less lateral strength than their ASCE 7-02 counterparts — about half the strength for the 20-story buildings. The collapse capacities predicted by these models were used by the ASCE 7 Seismic Subcommittee to inform its decision to reinstate the minimum base shear requirement (ASCE 7-05 Supplement #2, 2007).

These models also require the template files from the Structural Model Database page.

Stories Frame type Model ID Download
12-story Perimeter Frame 5013 Zip file
12-story Space Frame 5014 Zip file
20-story Perimeter Frame 5020 Zip file
20-story Space Frame 5021 Zip file

Need the template files?

Every model runs against the shared template files, processors, and instructions on the main database page.

Structural Model Database Ground Motion Sets